Buffer Tank Sunsystem, Model PR2 3000, Capacity 3000L, Two heat exchanging coils, Industrial

€3,191.00

Availability: In stock

SKU: 0000000318

Saving energy and money is achieved using buffer vessels of the Sunsystem PR2 series in the central heating system.


 

Print This Page

Product Description

The buffer tanks of series PR2 of the company SUNSYSTEM used for improving the performance and efficiency of heating, through the production and storage of hot water, which is used in the central space heating system. These specific buffer tanks allow the use of up to 3 external heat sources and optional kit for electric heating with nominal power  3kW, 4.5kW, 6kW or 7.5kW.

Product Features

  • Range of volumes of 300-3000 liters
  • Upright storage tank made of steel S235JR
  • Primer coated on the outside
  • CFC free soft PU-foam insulation with thickness of 100 mm 
  • PVC coating in RAL 9006 or other colors on demand
  • All threads are internal
  • Option for installing a heating element as back-up source of heat
  • Compressive strength 3 bar

Energy efficiency Buffers



Energy Efficiency Directive 2010/30 /EU, 
Regulation 812/2013:
 

Class E - capacity from 300 to 500 Liters;
Class Е - capacity from 800 to 1000 Liters;

Buffer tank PR2 series


1. Aesthetic PVC jacket with color RAL 9006
2. Primer coated outer surface
3. Removable insulation
4. Water tank of low-carbon steel
5. Lower coil S1
6. Upper coil S2

Additional Information

Warranty
2 Years

Weight (kg)
640.0000

Country of Manufacture
Bulgaria

Product Brand
Sunsystem

Water capacity/content (L)
3000

Heat exchanger coil
Two heat exchanger coils

Installation
Free standing

Dimension Height (mm)
2770

Height without insulation (mm)
2720

Diameter (mm)
1450

Diameter without insulation (mm)
1250

Minimum vertical clearance (mm)
2782

Insulation weight (kg)
35

Thermometer
Optional

Lower coil S1 heat exchanging surface (m²)
4.5

Lower coil S1 capacity (L)
27.7

Upper coil S2 heat exchanging surface (m²)
3.1

Upper coil S2 volume (L)
19.1

Buffer operating pressure (bar)
3

Coil operating pressure (bar)
16

Maximum coil operating temperature (°C)
110

Maximum buffer operating temperature (°C)
95

Recommended size of the boiler connected to the buffer (kW)
55 - 100

Sensor sleeve A (mm)
G 1/2'' / 822

Electric heating element B (mm)
G 1 1/2'' / 1356

Sensor sleeve C (mm)
G 1/2'' / 1832

Air vent sleeve D (mm)
G 1 1/2'' / 2720

Boiler heat carrier E (mm)
G 1 1/2'' / 2289

Heat carrier inlet F (mm)
G 1 1/2'' / 2125

Sensor sleeve G (mm)
G 1/2'' / 2052

Boiler heat carrier H (mm)
G 1 1/2'' / 1686

Boiler heat carrier J (mm)
G 1 1/2'' / 1346

Heat carrier inlet L (mm)
G 1'' / 1195

Boiler heat carrier M (mm)
G 1 1/2'' / 926

Sensor sleeve N (mm)
G 1/2'' / 672

Heat carrier outlet O (mm)
G 1'' / 390

Boiler heat carrier outlet P (mm)
G 1 1/2'' / 256

Certification
CE

Files & Manuals

There are no available files to download. Please contact us if you need any further information.